Expansion Joint Filler
   
 
SANWA foam is flexible, readily compressible, closed-cell polyethylene joint filler supplied in sheet form. Strip and special size are available. The product is designed for the use as an expansion joint filler in concrete, brick and block work, isolation joints and hinge joints. These are used as back up strips for elastromeric sealants.  

SANWA Foam 30

Density
:
30KG/M
Recovery Value
:
> 97%
Reduction is Mass
:
nil
Weathering Test
:
no disintegration
Water absorption
:
<0.7%
 
 

SANWA Foam 40

Density
:
40kg/m
Recovery Value
:
>36%
Reduction is Mass
:
nil
Weathering Test
:
no distintegration
Water absorption
:
<0.4%
 
 

SANWA Foam 60

Density
:
60kg/m
Recovery Value
:
>93%
Reduction is Mass
:
nil
Weathering Test
:
no disintegration
Water absorption
:
<0.35%
     
Advantages SANWA Foam WT or 80
- Low compression - accepts temperature cycles with minimal load transfer Density
:
80kg/m
- Excellent recovery - over 93% after release of load
Recovery Value
:
>97%
- Non-absorbent - closed-cell polyethylene prevents water absorption Reduction is Mass
:
nil
- Chemical resistant - inert to most dilute acids and alkali, resistant to oil and hydrocarbons Weathering Test
:
no disintegration
- Rot proof and CFC Free Water absorption
:
<.25%
- Excellent weather resistance - can be used in extreme hot or cold environment      
- Lightweight - ease of u se SANWA Foam NR300
- Easily worked - can be cut just with a sharp knife; easy to transport & carry Density
:
300kg/m
  Compressive
:
36 kpa
Application Compression Set
:
28.2%
SANWA foam is positioned to provide a surface sealing slot of required dimensions when used as an expansion or isolation joint filler in brick-work, to ensure that the sealing slot is free from mortar dropping or slurry bridging. Suitable adhesive may be used to position SANWAfoam sheet but ensure not to contaminate the surfaces of the sealing slot with adhesive. when SANWAfoam is used as a back up strips it used to regulate the depth of the sealing slot and ensure the movement of the joint sealant is not restricted by adhesion to the base of the sealing cavity. The size of the back-up strip should be greater than the joint width, and depressed sufficiently to provide the required sealing slot dimensions.        
Supply - in thickness(mm)
5,8,10,12,15,18,20,25,30,35,36,50,54 and80mm
     
Packing 1M x 2M per sheet
 
Storage
No shelf life if kept in cool and dry conditions

 